What is the FingerPass V8?

The FingerPass V8 is a biometric terminal intended for time management and physical access control. The terminal allows recording the arrival and departure events of the company’s employees (Check In and Check Out), managing of electromechanical and electromagnetic door-locks, turnstiles, and gateways; opening them upon successful verification of users by their fingerprints enrolled in the system. The FingerPass V8 also effectively solves major challenges faced by any company or organization: To ensure security and management personnel and provide a high level of safety combined with ease of use, reliability, and speed for higher security areas.

FingerPass V8

Why do I need it?

The FingerPass V8 gives you the ability to combine both time & attendance and physical access control into one easy to mount package. With other systems you need two other devices to the same thing as with one FingerPass V8 . It also provides you the ability to secure highly restricted areas by requiring people who provide two forms of authentication for entry. This is called Two Factor Authentication.

How does it work?

The Fingerpass V8 provides several methods of identification:
  • Fingerprint
  • Contactless RFID cards
  • PIN Codes
  • A combination of contactless cards, fingerprints and PIN-codes

Who uses it?

The Fingerpass V8 is ideal for companies that need to protect high security areas a durable, easy to maintain, and powerful device for both their physical access control and time & attendance systems.

Strengthened access control of critical facilities

The system supports a combination of two identifiers - fingerprints and contactless card. this features assist in specific applications where the security should be stronger then other locations

Visitors

Permanent employees are encouraged to use biometric identification. External visitors may use contactless cards during their visits

Identification Indications

The user is advised of the results of the identification process using a message on the display, the color indicator (LED) and voice messages.

Confidentiality of personal data

The terminal stores templates of fingerprints (mathematical representation).One can not restore an image of a fingerprint.

Interfaces

The FingerPass V8 supports all major interfaces used in control systems and access control - Ethernet, Wiegand, RS-232, and RS-485. Thus, the terminal can be used during new installations or as an add on into existing access control system. The terminal can be mounted on any surface and in any place with power socket and LAN.

Optical Scanning

Optical scanning is considered to be one of the most advanced identification (1:N) technology. It provides the highest quality and accuracy of identification regardless of the skin color and operates effectively with problematic fingers (dry or damaged skin, etc.).

Biometric Algorithms

The biometric identification algorithm is developed by BioLink. It's various versions are frequent members of independent tests regularly held by the American National Institute of Standards and Technology (NIST). It is approves by NIST, and considered to be one of the best Matching algorithms for 1:1 and 1:N modes V8ist today!

High Speed & Performance

The combination of the family of biometric fingerprint readers, and the applications provided by Bio-Metrica, provides one of the best performing systems with a very fast response time, accurate with very good performance ratios (low FAR / FRR / FTE, EER etc.)

General technical characteristics:

Supported cards MiFare, 1 Kb and 4 Kb, sensing range – up to 50 mm
Interfaces Ethernet 100BaseT, RS-232, RS-485, Wiegand 26 bit (Optional WiFi Available)
Screen Color 3.5 inches TFT screen with GUI Interface for ease of use
Inputs Access Control Interface for 3rd party electric lock, door sensor, exit button, alarm, door bell
Access Control Devices Supported Electromechanical devices and electromagnetic locks, turnstiles, gates, gates, etc.
Door control NO/NC relay with maximum switched current 2A
Maximum length of communication line (without amplifiers): 100 m
Power requirements (DC): 12V DC 1.5A
Operating temperature 0 ° C to +45 ° C; The recommended temperature for optimum scanning fingerprints from +10 ° C to +35 ° C
Humidity 20% - 80% (no condensation)
Enclosure wall-mountable
Weight 1.3 Kilograms
Size 189 mm x 136 mm x 44 mm (50 w/plate)
Alarm system Unauthorized persons access attempts, device disassembling/ damage, “alarm fingerprint” capturing

Fingerprint Scanner characteristics:

Fingerprint scanner (embedded) optical
Finger scanning window size 20 mm x 18 mm
Fingerprint image resolution 500 dpi
Fingerprint scanning speed 16 fingerprints per second
FAR (false acceptance rate) 0.0001%
FRR (false rejection rate) 0.0001%
Maximum number of fingerprint templates 8000
Number of transactions stored 200,000
“False Fingers” protection Built In
Fingerprint captured 150K ; 480x320 pixels
Light source Infrared LED

FingerPass TM

Compatible Applications:

Bio Time

Tags: